AGRM has long focused on the research and development, production, promotion, and application of high-temperature combustion technology and oxy-fuel burner system in industrial kilns, and has accumulated rich experience in the field of full oxygen combustion technology, from oxy-fuel burner design to manufacturing. Oxy Fuel Burner for natural gas designed to be placed in the forehearth providing temperature homogeneity throughout the glass.

Application:
  • Oxy-fuel Burner Systems for Glass Furnace
  • Oxy-Fuel Combustion for Ceramics Kiln
  • Oxy-fuel Burner for Metallurgy
  • Oxy-fuel Burner for Cement Rotary Kilns
  • Oxy-fuel Burner for Waste Incineration.
  • Oxy-fuel Burner Systems for Metals Production
  • Oxy-fuel Burner Systems for Secondary Non-ferrous Melting

AGRM Oxy-Fuel Burner For Sale

We can provide customers with a variety of mature full oxygen combustion burners, including the HR series with flat flames, the AL-VM series with variable kinetic energy, the low kinetic energy and low NOX series with multi-layer structure, the channel series for channel heating, and the LANCES series for local combustion.

BURNERS are essential for heating in almost all industrial furnaces, particularly in high-temperature industries. Equally important is the BURNER BLOCK, which works in conjunction with the BURNER.

HRc Series (Flat Flame)

extensive flame coverage

Get A Quote
Burner
Variable Kinetic Energy

adjustable flame length 15-25%

Get A Quote
Burner
LP

multi-layer structured flat flame burner

Get A Quote
Burner
CF

Fiber Feeder Heating in the Channel Series

Get A Quote
L-F

LANCES for Local Combustion, Conical flame

Get A Quote

works in conjunction with the BURNER

Get A Quote
Burner and Flame Features
  • Flat Flame
  • Adjustable Flame Length (Flame length and flame covering area can be adjusted through STAGING SWITCH).
  • Adjustable brightness of the flame
  • Local Atmosphere Adjustable in the Combustion Chamber
  • High Heat Transfer Efficiency
  • Easy Maintenance and Long Service Life
Get in touch with us immediately!

Oxy-fuel Burner Main Structure

Our burners can adapt to the following fuels, NG, LNG, heavy oil, Coal tar, light diesel oil, Petroleum coke, coke oven gas, rock stratum gas, etc; Application field, Common industrial kilns include glass kilns, ceramic kilns, metallurgical kilns, cement Rotary kiln, Incineration and other fields.

Burner
Burner
No.Items
1Burner block
2Adaptor
3Burner
4Clip
5Staging
6Set bolt
7Gasket 1
8Gasket 2
9Nature gas inlet
10Oxygen inlet
11Outlet of main nature gas + oxygen
12Outlet of regulating oxyg
Get in touch with us immediately!

Oxy-fuel Burner Technical Specification

No.Gas Fuel Burner Model ParameterRemake
1Firing Rate (Staged)0.02MW – 1.35MW 
2Flame Length (Staged)1.4m – 2.0mLength of Visible Light of Flame
3Flame Length (Unstaged)0.9 m– 2.6m 
4Max Oxygen Pressure69mbar 
5Max Nat. Gas Pressure55mbar 
6  Burner Block Size 220mmX190mmX305mmEach dimension of furnace DOG should be increased 
at least 10MM.
7Burner Block Weight32KgZM- 19
8Safe Oxy/Fuel Ratio≥1:1.8Purity of Oxygen≥92%
 9  Burner Fiitings1.5”MNPT, 1”MNPTOxygen Gas fuel
Get in touch with us immediately!
HRc Series (Flat Flame)

The HRc Series (Flat Flame) burner features a flat flame with easy maintenance and a long service life, adjustable flame length, low NOx emissions, and extensive flame coverage.

VM Series (Variable Kinetic Energy)

The VM Series Conical flame offers easy maintenance, a long service life, adjustable flame length (15-25%) by modifying the central oxygen opening, extensive flame coverage, and low kinetic energy.

Serial NumberModelMaximum PowerRatedPowerMinimum PowerFlame LengthSFlame LengthL
1VM 50120kW50 kW20 kW16002100
2VM 100240kW100 kW30 kW20002400
3VM 200480 kW200 kW50kW25003200
LP Series

The LP Series is a multi-layer structured flat flame burner with low kinetic energy and low NOx emissions. It offers easy maintenance and a long service life, along with adjustable flame length (0-35%) through the upper oxygen channel opening, and provides large flame coverage.

Serial NumberModelMaximum PowerRatedPowerMinimum PowerFlame Length SFlame Length L
10.5MKW25050070018002800
21MKW4001000150020003600
32MKW7002000300024004500
Get in touch with us immediately!
CF Series

CF Series for Fiber Feeder Heating in the Channel Series

  • Conical flame
  • Easy to maintain and long service life
  • Suitable for heating the material channel of FIBER kiln
  • Fuel: NG
  • Power: 0.04-0.12MMBTU
L-F Series

L-F Series LANCES for Local Combustion

  • Conical flame
  • Easy to maintain and long service life
  • Suitable for heating the discharge port and polishing the hot end of glass products
  • Fuel: NG
  • Power:0.04-0.12MMBTU

Oxy-fuel Burner Design

Get in touch with us immediately!

Oxy-fuel Burner Technical Specification

Get in touch with us immediately!
Oxyen Flow
Oxyen Back Pressure
Get in touch with us immediately!
Natural Gas Back-Pressure
staging flow vs valve positopn

Routine Maintenance

  • Daily Inspection items for each operation group: checking flame shape including length, width, thickness, flame brightness and uniformity, checking seal condition around burner body and the existence of overheat sections, checking conditions of burner body and burner blocks, checking conditions of gas supply pipeline;
  • Weekly operation items: (the specific frequency and content are determined according to the actual situation of the factory. It is recommended that the frequency will be once a week.) Checking and cleaning main oxygen nozzle hole of burner block (through the convenient inspection hole), pulling out the fuel nozzle and checking the status of the internal nozzle (conditions of burning loss, connection and ash accumulation).
  • Monthly operation items: checking the leakage of each sealing link, removing the inner fuel effuser of the fuel nozzle, cleaning and maintaining. (Eliminating carbon and ash accumulation, replacing if necessary.)
Get in touch with us immediately!

Safety Requirements

Inspection Requirements before Ignition

Distributed Control System(DCS) and Nature Gas Valve Manifolds:
  • Hand valve of valve manifolds inlet;
  • Water separator;
  • Front pressure gauge of pressure-relief valve;
  • Pressure-relief valve;
  • High-tension switch;
  • Low voltage switch;
  • Back pressure gauge of pressure-relief valve;
  • Gas flowmeter (temperature/pressure compensation);
  • Double automatic
  • safety globe valve;
  • Emergency stop button of valve manifolds;
  • Nature gas/oxygen sensors and
  • related linkage controls around valve manifolds;
  • Oxygen/nature gas flow ratio protection;
  • Furnace temperature interlocking protection
Get in touch with us immediately!
Distributed Control System(DCS) and Nature Gas Valve Manifolds:
  • Hand valve of valve manifolds inlet;
  • Water separator;
  • Front pressure gauge of pressure-relief valve;
  • Pressure-relief valve;High-tension switch;
  • Low voltage switch;
  • Back pressure gauge of pressure-relief valve;
  • Gas flowmeter (temperature/pressure compensation);
  • Double automatic
  • safety globe valve;
  • Emergency stop button of valve manifolds;
  • Nature gas/oxygen sensors and
  • related linkage controls around valve manifolds;
  • Oxygen/nature gas flow ratio protection;
  • Furnace temperature interlocking protection
In Front of the Burner:
  • Manual globe valve(oxygen, nature gas);
  • Oxygen check valve;
  • Natural gas check valve;
  • Hand held sensor for on-site gas leak detection near burner (owned);
  • Emergency stop button of site combustion (combustion valve manifolds includes)
Burner:

Pre-assembly has been carried out according to requirements.

Get in touch with us immediately!

Operation and Maintenance

  • The disassembly of burner and its parts shall be prohibited in operation (with oxygen/and/or natural gas).
  • The burner shall not be ignited before the minimum temperature in the combustion space is lower than 800DC (unless UV system is used and safe linkage is ensured)

Precondition of Combustion after the oxidizer/fuel fed into the burner

  • The disassembly of burner and its parts shall be prohibited in operation (with oxygen/and/or natural gas).
  • The burner shall not be ignited before the minimum temperature in the combustion space is lower than 800DC (unless UV system is used and safe linkage is ensured)

If the temperature inside the furnace is lower than the fuel/oxidizer autoignition temperature (within all reaching range of the fuel/oxidizer)

  • Using an ignition device to aid the ignition.
  • Using UV to monitor flame, interlinking and controling with the fuel/oxidizer control system.
  • Important inspection requirements in the process of combustion.
  • Inspecting leakages of fuel/oxidizer.
  • Inspecting whether the flame is normal.
  • Inspecting whether there is any anomaly in the composition of the exhaust gas
Get in touch with us immediately!

Burner emergency disposal/safety requirements (when running the burner in the factory)

  • When replacing or maintaining the burner, in order to prevent the risk of combustion caused by oxygen or natural gas leakage, fan blowing shall be applied on site.
  • The oxygen and natural gas supply to the burner shall be stopped immediately if combustion occurs outside the burner.
  • If oxygen or natural gas is found to be enriched around the burner (no obvious leakage), the supply of oxygen and natural gas to the burner shall be shut off immediately. Meanwhile, the fan shall be used to blow air locally to the burner. Locating the source of the leak and deal with it.
  • It is not permitted to pull out the nature gas nozzle when the nature gas is being supplied.
  • When the combustion has been stopped for over 5 minutes, the burner metal parts shall be removed and the holes on burner blocks shall be sealed